ELEKTROMATEN SE drives are special drives for sectional doors with spring compensation. Installation usually takes place directly on the shaft of the gate.
ELEKTROMATEN SE drives consist of: a worm gear with hollow shaft, a device for emergency manual operation, integrated limit switches and electric motor or engine with integrated cycloconverter (SE 6.65 DU) or motor with integrated frequency converter (SE 6.80 FU / SE 14.80 FU).
Drive unit with integrated cycloconverter (SE 6.65 DU) or a drive integrated with a frequency converter (FU SE 6.80 / 14.80 FU SE) in communication with the controller TS 970, TS 971 and TS 981.
Special versions
Tests and certificates
ELEKTROMATEN and FU-motors tested in accordance with:
2 working 2 emergency, 2 additional
Electronic position sensor, without a loss of voltage positioning
SE 5.24 | SE 5.24 WS | SE 9.15 | SE 9.15 WS | SE 9.20 | SE 9.20 WS | SE 9.24 | ||||
Output shaft torque |
Nm | 50 | 50 | 90 | 90 | 90 | 90 | 90 | ||
Output shaft torque |
rev / min | 24 | 24 | 15 | 15 | 20 | 20 | 24 | ||
Ø output shaft |
mm | 25,4 | 25,4 | 25,4 | 25,4 | 25,4 | 25,4 | 25,4 | ||
The maximum resistive torque |
Nm | 200 | 200 | 450 | 450 | 450 | 450 | 450 | ||
The maximum weight of the door |
N | 2500 | 2500 | 4000 | 4000 | 4000 | 4000 | 4000 | ||
An output rotational speed of a frequency converter otw./zam.z |
rev / min | 42 / 30 | -- | 26 / 26 | 26 / 26 | 36 / 30 | 36 / 30 | 42 / 30 | ||
Engine power |
kW | 0,3 | 0,37 | 0,3 | 0,3 | 0,3 | 0,3 | 0,37 | ||
Operating voltage |
V | 3~230/400 | 1N~230 | 3~230/400 | 1N~230 | 3~230/400 | 1N~230 | 3~230/400 | ||
Operating frequency |
Hz | 50 | 50 | 50 | 50 | 50 | 50 | 50 | ||
Operating current |
A | 1,9 / 1,1 | 3,5 | 2,6 / 1,5 | 2,6 / 1,5 | 2,6 / 1,5 | 2,1 / 1,2 | 3.9 | ||
Max. Number of starts per hour | 12 | 12 | 20 | 16 | 20 | 16 | 20 | |||
The range limit switch |
20 | 20 | 20 | 20 | 20 | 20 | 20 | |||
Drive weight kg |
kg | 11 | 13 | 13 | 17 | 13 | 17 | 13 |
SE 9.24 WS | SE 9.30 | SE 14.15 | SE 14.21 | SE 6.65 DU | SE 6.80 FU | SE 14.80 FU | FU 8 | ||||
Output shaft torque |
Nm | 90 | 90 | 140 | 140 | 60 | 60 | 140 | 80 | ||
Output rotational speed of the open closing |
otwierania | rev / min | 24 | 30 | 15 | 21 | 20-65 | 15-80 | 10-80 | 12-60 | |
zamykania | 20-30 | 15-30 | 10-30 | 12-30 | |||||||
Ø output shaft |
mm | 25,4 | 25,4 | 25,4/31,75 | 25,4/31,75 | 25,4/31,75 | 25,4/31,75 | 25,4/31,75 | 25,4 | ||
The maximum resistive torque |
Nm | 450 | 450 | 600 | 600 | 450 | 450 | 600 | 300 | ||
The maximum weight of the door |
N | 4000 | 4000 | 6000 | 6000 | 3000 | 3000 | 6000 | 3000 | ||
An output rotational speed of a frequency converter otw./zam.z |
rev / min | -- | 52 / 30 | 26 / 26 | 36 / 30 | -- | -- | -- | -- | ||
Engine power | kW | 0,45 | 0,37 | 0,35 | 0,45 | 0,45 | 0,4 | 0,85 | 0,5 | ||
Operating voltage |
V | 1N~230 | 3~230/400 | 3~230/400 | 3~230/400 | 3~400 | 1N~230 | 1N~230 | 1N-230 | ||
Operating frequency |
Hz | 50 | 50 | 50 | 50 | 50 | 50 / 60 | 50 / 60 | 50/60 | ||
Operating current |
A | 3,9 | 2,1 / 1,2 | 3,3 / 1,9 | 4,5 / 2,6 | 0,8 | 8 | 6,6 | 2,1 | ||
Max. Number of starts per hour |
16 | 20 | 16 | 16 | 20 | 40 | 40 | 36 | |||
The range limit switch |
20 | 20 | 20 | 20 | 20 | 20 | 20 | 14 | |||
Drive weight kg |
kg | 16 | 14 | 18 | 14 | 16 | 18 | 24 | 9 |